Electric Motor ABB brand M3AA 90LC4 1.1kW B34 IE3 3GAA092530-ASK ALUMINIUM FRAME
When placing an order, please state the following
minimum data in the order, as in the example.
The product code of the motor is composed in accor-
dance with the following example.
Technical data for totally enclosed squirrel cage three phase motors IP 55 – IC 411 – Insulation class F, temperature rise class B IE2 class
Single-speed motors of size 56 to 132 are stamped with
50 and 60 Hz at voltage code S and D. The current
rating for each voltage range is specified on the rating
plate. It represents the highest current that can exist
within the voltage range at the rated output. The power
factor and speed specified on the rating plate apply at
400 V 50 Hz and 460 V 60 Hz.
M3AA 280 has feet and D-end shield of cast iron.
M3AA 250 SMB 2-pole, high output version, as well as
M3AA 280 2-pole have cast iron feet and bearing
shields.
The flange bearing shields of sizes 180 to 280 are made
of cast iron
Axially-locked bearings
The terminal block is provided with
6 terminals for connecting Cu-cable.
The terminals are marked in
accordance with IEC 60034-8.
Single-speed motors of size 160 to 280 are stamped
with 50 and 60 Hz at voltage code S and D. The rating
plate is arranged in the form of a table with values for
current, power factor and motor speed at six voltages.
IE Class Data (50 Hz):IE Class IE2
Full Load (100%) 89.7 %
Partial Load (75%) 90.4 %
Partial Load (50%) 89.4 %
IE Class Data (60 Hz):IE Class IE2
Full Load (100%) 91.3 %
Partial Load (75%) 91.5 %
Partial Load (50%) 90.2 %
M3AA 80 MB2 0.75kW IE3 3GAA081320-ASK;
M3AA 112 MC6 2.2kW IE3 3GAA113330-ASK;
M3AA 80 MC2 1.1kW IE3 3GAA081330-ASK;
M3AA 132 MC6 3kW IE3 3GAA133330-ASK;
M3AA 90 LC2 2.2kW IE3 3GAA091530-ASK;
M3AA 132 MD6 4kW IE3 3GAA133340-ADK;
M3AA 90 LB2 1.5kW IE3 3GAA091520-ASK;
M3AA 132 ME6 5.5kW IE3 3GAA133350-ADK;
M3AA 100 LC2 3kW IE3 3GAA101530-ASK;
M3AA160MLA6 7.5kW IE3 3GAA163410-ADK;
M3AA 112 MB2 4kW IE3 3GAA111320-ADK;
M3AA160MLB6 11kW IE3 3GAA163420-ADK;
M3AA 132 SB2 5.5kW IE3 3GAA131120-ADK;
M3AA180MLA6 15kW IE3 3GAA183410-ADK;
M3AA 132 SC2 7.5kW IE3 3GAA131130-ADK;
M3AA180MLB6 18.5kW IE3 3GAA183420-ADK;
M3AA160MLA2 11kW IE3 3GAA161410-ADK;
M3AA90LD4 1.5kW 3GAA092540-ASE;
M3AA160MLB4 15kW IE2 3GAA162420-ADG;
M3AA160MLB2 15kW IE3 3GAA161420-ADK;
M3AA90LB6 0.75kW 3GAA093520-ADE
M3AA160MLC4 18.5kW IE2 3GAA162430-ADG;
M3AA160MLC2 18.5kW IE3 3GAA161430-ADK;
M3AA90LB6 0.75kW 3GAA093520-ASE;
M3AA160MLD4 22kW IE2 3GAA162440-ADG;
M3AA180MLA2 22kW IE3 3GAA181410-ADK;
M3AA90LD6 1.1kW 3GAA093540-ADE
M3AA160MLA6 7.5kW IE2 3GAA163410-ADG;
M3AA160MLD2 22kW IE3 3GAA161440-ADK;
M3AA90LD6 1.1kW 3GAA093540-ASE;
M3AA160MLB6 11kW IE2 3GAA163420-ADG;
M3AA180MLB2 30kW IE3 3GAA181420-ADK;
M3AA90S8 0.37kW 3GAA094100-ADE
M3AA160MLC6 15kW IE2 3GAA163430-ADG;
M3AA180MLC2 37kW IE3 3GAA181430-ADK;
M3AA90S8 0.37kW 3GAA094100-ASE;
M3AA160MLA8 4kW IE2 3GAA164410-ADG;
M3AA 80 ME4 0.75kW IE3 3GAA082350-ASK;
M3AA90L8 0.55kW 3GAA094500-ADE
M3AA160MLB8 5.5kW IE2 3GAA164420-ADG;
M3AA 90 LD4 1.5kW IE3 3GAA092540-ASK;
M3AA90L8 0.55kW 3GAA094500-ASE;
M3AA160MLC8 7.5kW IE2 3GAA164430-ADG;
M3AA 90 LC4 1.1kW IE3 3GAA092530-ASK;
M3AA100LB2 3kW 3GAA101520-ADE
M3AA180MLA2 22kW IE2 3GAA181410-ADG;
M3AA 100 LE4 2.2kW IE3 3GAA102550-ASK;
M3AA100LB2 3kW 3GAA101520-ASE;
M3AA180MLB2 30kW IE2 3GAA181420-ADG;
M3AA 100 LF4 3kW IE3 3GAA102560-ASK;
M3AA100LC4 2.2kW 3GAA102530-ADE
M3AA180MLA4 18.5kW IE2 3GAA182410-ADG;
M3AA 112 MB4 4kW IE3 3GAA112320-ADK;
M3AA100LC4 2.2kW 3GAA102530-ASE;
M3AA180MLB4 22kW IE2 3GAA182420-ADG;
M3AA 132 MB4 5.5kW IE3 3GAA132320-ADK;
M3AA100LD4 3kW 3GAA102540-ADE
M3AA180MLC4 30kW IE2 3GAA182430-ADG;
M3AA 132 MC4 7.5kW IE3 3GAA132330-ADK;
M3AA180MLB6 18.5kW IE2 3GAA183420-ADG;
M3AA180MLA6 15kW IE2 3GAA183410-ADG;
M3AA160MLA4 11kW IE3 3GAA162410-ADK;
M3AA180MLA8 11kW IE2 3GAA184410-ADG;
M3AA160MLB4 15kW IE3 3GAA162420-ADK;
M3AA 90 LD6 0.75kW IE3 3GAA093540-ASK;
M3AA180MLA4 18.5kW IE3 3GAA182410-ADK;
M3AA 100 LE6 1.1kW IE3 3GAA103550-ASK;
M3AA180MLB4 22kW IE3 3GAA182420-ADK;
M3AA 100 LF6 1.5kW IE3 3GAA103560-ASK;
M3AA160MLC4 18.5kW IE3 3GAA162430-ADK;
Motors that will be operated in very humid or wet
environments and especially under intermittent duty
should be provided with drain holes. The appropriate IM
designation, such as IM 3031, is specified on the basis
of the method of mounting the motor.
Motors are provided with closable plastic plugs in the
drain holes (see diagram below). The plugs will be open
on delivery. When mounting the motors it should be
ensured that the drain holes face downwards. In the
case of vertical mounting, the upper plug must be hammered home completely. In very dusty environ-
ments both plugs should be hammered home.
Sizes 56 to 63 are supplied as standard with drain holes
on D-end while sizes 71 to 280 are supplied with drain
holes both on D-end and N-end.
When mounting arrangement differs from foot mounted
IM B3, please mention variant code 066 when ordering.
See variant codes 065, 066 and 076 under the heading
“Drain holes”.
Model Type | 3 phase Induction motor |
---|---|
(IE) Efficiency Classes | IE3 |
Feature | General Purpose |
Manufacturer | ABB |
Frame Size | 90L |
Insulation Class | F |
Output Power(KW) | 1.1KW |
Protection | IP55 |
Housing Material | Aluminum Frame |
Enclosure | Totally Enclosed Fan Cooled (TEFC) |